Air Displacement:      0.7-7m³/min
Discharge pressure:              0.8-1.3bar
Horsepower:              7.5-45kW
Weight:                      140-500kg

We're here to help:

Easy ways to get the answers you need.

overview

 Through the pressure sensor, the permanent magnet variable frequency screw ar compressor senses the actual pressure and air consumption in the system intime, and changes the speed of the alr compressor through the precise contro of the lectricaland frequency converter, so as to adiust the system pressure toachieve the on-demand output of comoressed air; when the air consumption of the system s reduced, the ar compressor reduces the speed to reduce theoutput of compressed air, and vice versa, the motor speed is increased to increase the amount of compressed air to maintain a stable system pressure.  

 

Features

1. Stable discharged pressure
The stepless adiustment characteristtcs of the inverter used by the permanent magnet variable frequency screw air compressor can achieve high-sped adjustment and controlof the pressure through the intemal adjustment of the controler or the inverter. Compared with the upper imit swtch controlof power frequency air compressor operation, the air pressure stability is exponentially improved.
2. Start without impact
Since the inverter itsel is a sot start device, the maximum starting curent is about twice the rated ourent, and compared with the power frequency start -up isgeneraly more than 6 times the rated curen, the starting impact is very smal. This impact is not only on the power grid, but HFo on the entire mecharical system, which can be greatly reduced.
3. More energy saving
The inverter adusts motor speed in real tme according to the actual ar consumption, and the ar compressor can be automaticaly dormant when the arconsumption is low, which greatly reduces the loss of energy.
4. Low noise
Since the operating frequency is less than the power frequency during stable operation, the mechanical noise is reduced and the mechanical wear is smal; Thecapacity requirement of the air tank is small.
Zhengzhou Hanfa Prospecting Machinery Co., Ltd.

 

Technical Data

Model HF-08A/YC HF-11A/YC HF-15A/YC HF-18.5A/YC HF-22A/YC HF-30A/YC HF-37A/YC HF-45A/YC
Air  delivery(M³/min)
/Discharge pressure(Mpa)
1.0/0.8
0.85/1.0
0.7/1.3
1.5/0.8
1.3/1.0
1.1/1.3
2.3/0.8
2.1/1.0
1.5/1.3
2.8/0.8
2.6/1.0
2.3/1.3
3.2/0.8
3.0/1.0
2.8/1.3
5.0/0.8
4.8/1.0
3.2/1.3
6.2/0.8
6.0/1.0
5.0/1.3
7.0/0.8
6.8/1.0
6.2/1.3
Power(kW) 7.5  11  15  18.5  22  30  37  45 
Voltage 380V/50HZ
Driven mode Direct
Lubricant volume(L) 10  10  18  18  18  25  25 
Noise(dB(A)) 64±2 64±2 64±2 68±2 68±2 68±2 72±2 72±2
Starting mode Variable frequency starting
Overall dimension(L*W*H)(mm) 760*620*840 1000*750*1020 1000*750*1020 1180*850*1160 1180*850*1160 1180*850*1160 1280*1000*1290 1280*1000*1390
Weight(KG) 140  240  240  350  350  350  500  500 
Outlet pipe diameter RP1/2 RP3/4 RP3/4 RP1 RP1 RP1 RP11/2 RP11/2
Working environment temperature(℃) -5℃~+45℃
Exhaust temperature(℃) ≤Ambient temperature+15℃
Oil content(PPM) ≤3PPM
Rotary speed 3000 

 